When a pressure vacuum breaker backflow assembly is installed at your home or business, it will most likely need to be installed on Schedule 80 PVC, galvanized, or copper pipe & fittings to comply with local code. The pressure vacuum breaker backflow assembly must always be installed at a minimum of 12 inches above the highest irrigation head, but must not exceed a maximum height of 5 feet.
Any backflow assembly must be tested annually to comply with local code. They must be tested by a state-certified backflow tester with a pressure differential type gauge. If the backflow fails the test, it must be repaired by a state-certified tester that is also certified to repair the unit. The results must then be logged with your local municipality by the test/repair contractor.
If you have a pressure vacuum breaker backflow assembly installation at either your home or business that requires an annual test, please call us at 407-302-2227
to make an appointment. We perform backflow tests & repairs in the Orlando or Central Florida area. If a backflow assembly is not installed at your property, we can recommend & install the correct type to protect your potable water supply from contamination from your irrigation sprinkler system.